pulse output flow meter in albania


Liquid turbine flowmeter with pulse output – k-factor explained. the so-called pre-scaler board fits inside the flowmeter housing of the series 800, 900 and 1000 and receives the pulses directly from the hall effect detector. as described above, as the flowmeter is calibrated at the factory the k
Electric flow meter with scaled pulse output, flow rates up to 30 gpm (113 lpm), ±5% accuracy
The series wmt2 multi-jet water meter is a series of mechanical, water totalizing meters that display the total water usage in gallons or m3 and provide a reed switch output proportional to flow rate. they are available in a range of body sizes and include npt or bspt couplings. not for potable water use, brass contains lead in excess of low lead limits.
Flow meter may be supplied with two lmes, offering up to four pulse outputs. alternate pairs across the two lmes are also 90° electrically out of phase. series 1200 and 1500 liquid turbine flow meters can be fabricated with adjacent tube sections. each meter is precisely calibrated before shipment. the meter systems are used to provide measurement


If you need additional information, or have any special requests for equipment, please fill out the following form.




  • Liquid turbine flowmeter with pulse outputjlc international

    Liquid turbine flowmeter with pulse output – k-factor explained. the so-called pre-scaler board fits inside the flowmeter housing of the series 800, 900 and 1000 and receives the pulses directly from the hall effect detector. as described above, as the flowmeter is calibrated at the factory the k …

  • Pulse output device (pod) liquid controls

    Square wave: single channel output (channel a or channel b) quadrature channel output channel a and channel b; pulse timing: nominal 50% on and 50% off; rise/fall time of pulse: <5 μs; operating temperature range:-40 to 176 °f (-40 to 80 °c) humidity range: 0-100 %, noncondensing; output: current sinking100 ma maximum in “on” state

  • Fluid handling rfq form macnaught usa

    M series pulse output exploded view & part numbering m series high pressure exploded view & part numbering m1 ¼” flow meter 0.13-26 gph technical specifications

  • Flow meters instrumart

    Electric flow meter with scaled pulse output, flow rates up to 30 gpm (113 lpm), ±5% accuracy

  • Turbine flow meters liquid flow meters emerson us

    Turbine meters are simple to operate and maintain, and in service worldwide as a reliable, cost-effective method for achieving accurate flow measurement. turbine flow meters are designed to maximize throughout and minimize pressure drop, maintain high flow rates over an extended flow range and offer pulse output that is linear to the flow rate.

  • Domestic water meter kit (caleffi) free bim object for ...

    Flow meter (mi001), with pulse output shut-off ball valve with male terminal. keycode:794140_end

  • What is the pulse output?flow control network

    Dec 07, 2012 · what is the pulse output? some users want to totalize the flow using a pulsed output instead of a 4-20 output or in accordance with it. the pulses will be proportional to flowrate; for example, a number of standard cubic feet (scf) per pulse.

  • Series wmt2 multi-jet water meter with pulsed output is ...

    The series wmt2 multi-jet water meter is a series of mechanical, water totalizing meters that display the total water usage in gallons or m3 and provide a reed switch output proportional to flow rate. they are available in a range of body sizes and include npt or bspt couplings. not for potable water use, brass contains lead in excess of low lead limits.

  • Water flow meter pulse output, water flow meter pulse ...

    A wide variety of water flow meter pulse output options are available to you, there are 3,896 water flow meter pulse output suppliers, mainly located in asia. the top supplying countries are china (mainland), hong kong, and singapore, which supply 98%, 1%, and …

  • Best way of totalizing flow? [text]plcs ...

    Hi, what is the best way of totalizing flow, number 1 or 2? 1. using a flow-meters built-in totalizer pulse, that will pulse for say every 10m3. then you only count pulse and multiply with some conversion factor. what if the plc lose pulses? (using profibus and no speed counter input, task interrupted, etc) 2.

  • Technical guide: daniel liquid turbine flow meters

    Flow meter may be supplied with two lmes, offering up to four pulse outputs. alternate pairs across the two lmes are also 90° electrically out of phase. series 1200 and 1500 liquid turbine flow meters can be fabricated with adjacent tube sections. each meter is precisely calibrated before shipment. the meter systems are used to provide measurement

  • Pulse output device (pod) alpeco ltd

    The pulse output device (pod) converts the rotary motion of liquid controls flowmeters into a high resolution, unscaled pulse stream that equal the volumetric measurements of the meter. the pulse output device mounts directly to the front cover of the flow meter in place of the packing gland.

  • Om series oval gear meters (medium capacity) flomec

    Medium capacity oval gear meters (om series) the flomec® om medium capacity oval gear meters are great for medium flow ranges and have the ability to handle a wide range of fluid viscosities.

  • Lead free water meterswm-nlc series by flows

    Pulse output: pulse output is needed when you need to connect your meter to a pulse reader in order to read data away from where the meter is installed (see kal-d06 or t210 for lcd pulse read-out devices). this is perfect for applications where installation location makes it difficult or impossible to read the meter or in the case of multiple properties that need to be read in a common area.